Polymer gel measurement of dose homogeneity in the breast: comparing MLC intensity modulation with standard wedged delivery

, , and

Published 1 April 2003 Published under licence by IOP Publishing Ltd
, , Citation P A Love et al 2003 Phys. Med. Biol. 48 1065 DOI 10.1088/0031-9155/48/8/308

0031-9155/48/8/1065

Abstract

Polymer gel dosimetry has been used to measure the radiotherapy dose homogeneity in a breast phantom for two different treatment methods. The first 'standard' method uses two tangential wedged fields while the second method has three static fields shaped by multileaf collimators (MLCs) in addition to the standard wedged fields to create intensity modulated fields. Gel dose distributions from the multileaf modulation treatment show an improved dose uniformity in comparison to the standard treatment with a decreased volume receiving doses over 105%.