Brought to you by:

Using Euler buckling springs for vibration isolation

, and

Published 14 March 2002 Published under licence by IOP Publishing Ltd
, , Citation J Winterflood et al 2002 Class. Quantum Grav. 19 1639 DOI 10.1088/0264-9381/19/7/355

0264-9381/19/7/1639

Abstract

Difficulties in obtaining ideal vertical vibration isolation with mechanical springs are identified as being due to the mass of the elastic element which is in turn due to its energy storage requirement. A new technique to minimize this energy is presented—being an Euler column undergoing elastic buckling. The design of a high performance vertical vibration isolation stage based on this technique is presented together with its measured performance.

Export citation and abstract BibTeX RIS