X-ray resonance exchange scattering from ferromagnets: A new approach and its application to EuS

, , , , and

2002 EDP Sciences
, , Citation D. Hupfeld et al 2002 EPL 59 284 DOI 10.1209/epl/i2002-00239-3

0295-5075/59/2/284

Abstract

We have employed a new experimental configuration to measure ferromagnetic X-ray resonance exchange scattering (XRES) from a EuS single crystal. Using polarisation analysis we could achieve a magnetic-scattering intensity stronger than charge scattering resulting in an asymmetry ratio as large as Ra = 0.67 at the EuLII edge. By a combined refinement of the dependencies of the scattered intensity on the energy and the applied magnetic field we could uniquely determine spectroscopic information such as the 5d conduction band exchange splitting epsilon = 0.27(1) eV.

Export citation and abstract BibTeX RIS

10.1209/epl/i2002-00239-3