The following article is Open access

Invitro toxicity test and searching the possibility of cancer cell line extermination by magnetic heating with using Fe3O4 magnetic fluid

, , , , , , , , and

Published under licence by IOP Publishing Ltd
, , Citation Pham Hoai Linh et al 2009 J. Phys.: Conf. Ser. 187 012008 DOI 10.1088/1742-6596/187/1/012008

1742-6596/187/1/012008

Abstract

A Fe3O4 based magnetic fluid with different concentrations ranged between 0.15 ng/cell to 10 ng/cell (nano gram/cell) was used in the in vitro toxicity test on several cancer cell lines, Sarcoma 180, HeLa and H358. It shows that the fluid with a concentration of Fe3O4 below 1.2 ng/cell is completely non-toxic for these cell lines. Even through in the presence of the highest concentration of 10 ng/cell, the cell viability still reaches more than 60%. The magnetic fluid with Fe3O4 concentration of about 0.1 ng/cell was also used to search ex-vivo the possibility of Sarcoma 180 extermination by magnetic heating with an AC field of 120Oe and 184 KHz. The result shows that after a heat treatment for 30 min., 40% of Sarcoma 180 cells was killed.

Export citation and abstract BibTeX RIS

Please wait… references are loading.
10.1088/1742-6596/187/1/012008