Performance of TOF-RPC for the BGOegg experiment

, , , and

Published 28 November 2016 © 2016 IOP Publishing Ltd and Sissa Medialab srl
, , 13th Workshop on Resistive Plate Chambers and Related Detectors (RPC2016) Citation N. Tomida et al 2016 JINST 11 C11037 DOI 10.1088/1748-0221/11/11/C11037

1748-0221/11/11/C11037

Abstract

We constructed a new time-of-flight (TOF) detector consisting of resistive plate chambers (RPCs) to measure particle energy in the BGOegg experiment. The BGOegg-RPC has a unique feature which enables us to cover a large area with a small number of readout channels. For this purpose, we developed the RPC with a strip size of 2.5 cm × 100 cm. The BGOegg-RPC covers an area of 320 cm × 200 cm with only 256 channels of readout electronics. In case of large readout RPCs, an originated signal is distorted and dispersed during propagation. In addition, there happens a signal reflection at the end of the strip. Although we designed the BGOegg-RPC and front-end electronics with minimized signal reflection, a small reflection still remained, deteriorating the resulting time resolution. After establishing calibration and correction methods to improve the performance of the BGOegg-RPC, we obtained the time resolution of σ ∼ 60 ps around the central region of strips.

Export citation and abstract BibTeX RIS

10.1088/1748-0221/11/11/C11037